Sensaphone Power and Temperature Monitor Environmental/Process monitoring over telephone lines with full programming capabilities!

The Remote Telemetry System for Environmental and Industrial Monitoring, Communication and Control

EXPRESS II offers a comprehensive package of standard monitoring and control features, plus powerful expansion options so that you can customize the system for your specialized needs or add on as your applications grow. Easy to install, program and expand, EXPRESS II may be the last monitoring and control system you ever need to buy.

Quick View
Built-in Power failure, Sound level, Backup Battery Voltage
Inputs Expandable up to 40 Inputs 8 Universal included: Dry Contact, Temperature, 4-20mA, 0-5VDC, Run Time, Pulse Count
Outputs 1 Form-A Relay included, expandable up to 17
Notification 48 custom voice or numeric pager numbers
Special Features NEMA-4X Sealed weatherproof housing, input expandability
Express 6700

model FGD6700 Just $1796 US$ 
buy_on_line
or just call toll free 1 800 296 3910!

cc
Expansion Card The robust Sensaphone Express II features advanced monitoring capabilities, plus allows for expansion of to 40 input/output channels. Easy to install, program, and expand, Express II can meet the needs of your system both today and tomorrow. The Express II is as flexible as your application requires, with features like built-in power failure monitoring, 8 universally-configurable alarm inputs, and an on-board relay output for manual or automatic switching.

It offers a wide range of temperature sensing (-85˚F to 300˚F), 48 user-programmable dial out numbers, and complete remote touch-tone programming capability.

Descriptive messages can be recorded for site identification and for each alarm input. Alarm-specific dialing and programmable call schedules allow users to customize the Express II’s dialing process.

The Express II is equipped with a gel-cell rechargeable battery that will provide 12 hours of backup time. The unit is housed in a NEMA-4X fiberglass enclosure with a front panel LCD and dual-color LEDs to indicate input status to on-site personnel. All programming settings and voice message are stored in nonvolatile memory.

 

FEATURES

  • 8 standard universally configurable inputs/expandable to 40
  • 32 additional channels for input/output expansion
  • Built-in power failure and sound level monitoring
  • Built-in relay output for manual or automatic switching
  • Digital speech recording allows the user to record custom ID and input messages
  • Complete programming access using the local keypad or via remote touch-tone phone
  • Dials up to 48 user-programmable numbers
  • Alarm specific dialing and phone lists allow the user to customize the dialing process
  • Housed in a NEMA-4 thermoplastic enclosure with a 12-hour Gel Cell rechargeable battery backup
  • Front panel LCD and LEDs indicate input status to on-site personnel

MONITORING

Express II is equipped with 8 universal inputs, configurable as dry contact, pulse count, 0-5V or 4-20mA analog, or temperature. Easy to install expansion cards let you increase your monitoring capacity by an additional 32 universal input channels. Each input, whether standard installed or expanded, is fully programmable and complete with a two-color LED to locally indicate the alarm status. Express II also features built-in AC power monitoring and built-in microphone for sound level monitoring.

COMMUNICATIONS
The system works over standard phone lines to deliver recorded alarm messages to up to 48 phone numbers. Call progress detection ensures that the crucial alarm call goes through, with no wasted time on busy-signals or no answers. Alarm specific dialing and phone list features allow you to customize the dialout process. The digital display indicates current alarm status and phone activity. The standard local serial port allows Express II to print alarm activity to a local printer.

MESSAGING
Digital speech technology allows you to record your voice for the dialout alarm messages and ID message. When Express II dials out for an alarm, the system recites your personalized voice message. This feature is especially useful for service personnel if you expand the input capabilities. Your creativity and Express II's flexibility enable you to have extensive monitoring capacity without confusion. All recorded voice messages are stored in nonvolatile memory.

PROGRAMMABILITY
Express II is fully programmable via the local keypad or remotely by touch-tone phone. Menu-style voice guidance makes programming simple and provides easy access to all parameters, whether you are calling in or using the keypad. Nonvolatile memory ensures that your programming is not lost during a power failure or storage.

HARDWARE
Express II is equipped with one relay output that can be programmed to control automatically or manually. Expansion cards allow you to increase Express II's output capacity by up to 32 relay output channels. Express II is housed in a NEMA-12 thermoplastic enclosure with 12-hour rechargeable Gel Cell battery backup.

Other popular Models to choose from.
new Model 400 Replaces the 1104, 1114, 1104 CottageSitter, 1104 RC and 1104 BS !!
new
Model 800 Replaces the 1108, 1118, 1108 CottageSitter, 1108 RC and 1108 BS !!
 
Model 1400 Advanced Features in a NEMA4X enclosure. 4 Inputs
 
Model 1800 8 Inputs in a NEMA4X enclosure with alpha numeric paging and web posting!
  Model 2800 Wireless System includes full analog capability so actual values can be monitored.
 
Model 2000 With email, fax, data logging capability
 
StationSitter Robust pump controller and AutoDialer
 
Scada 3000 Fully integrated control system
About Us Contact Us Privacy Policy Dealers Downloads Surplus Items Satisfaction Testimonials Returns