Specifications:
- Switch is U.L. listed.
- 1 Amp Max at 24 VDC.
- Recommended < 250ma.
- 24 inch lead wires (20 AWG)
- Operating temperature not to exceed 90
deg. Celsius.
Installation:
- Mount float slightly above
point where the water level activates the sump pump.
- Connect electrical leads
to the applicable circuit.
- Use of a water-tight
splice is recommended.
- Test to insure proper operation.
- To change circuit from N.C.
to N.O., remove "C" clip, reverse float, reinstall "C" clip.
- When connecting to an inductive
load an arc suppression device should be put in parallel
with the load to avoid damaging the switch.
|
Features:
- Low
cost.
- Simple
construction.
- High
reliability design.
- Made
of non-corroding plastic materials.
- Stainless
steel hose clamp for easy mounting.
- Sealed
reed switch provides high isolation when pump wiring breaks
down.
- Will
operate totally submerged.
- Unique
reversible float allows for N.O. or N.C. switch circuit.
- Fits
virtually all sizes and types of return pipes.

|
|